Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.616
Filtrar
1.
Clin Ophthalmol ; 18: 937-942, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38562644

RESUMO

Purpose: To quantify metamorphopsia in patients with resolved idiopathic Central Serous Chorioretinopathy (CSCR) using M-CHARTS and compare the results with the traditional Amsler grid and optical coherence tomography (OCT). Patients and Methods: For the purpose of this study, all consecutive cases of patients with resolved CSCR were evaluated for metamorphopsia (using the standard Amsler grid and M-CHARTS) and spectral domain OCT. The OCT images were analyzed for the following five parameters: central macular thickness, pigment epithelial detachment, retinal pigment epithelial bumps, discontinuation in the inner segment/outer segment junction or the external limiting membrane, fibrinous exudates in the subretinal space, and hyperreflective dots in the intraretinal and/or subretinal layer. Binary logistic regression was used to find the association between metamorphopsia and foveal morphology. Cohen's Kappa was used to determine the agreement between the M-CHARTS and Amsler grid for diagnosing metamorphopsia. The sensitivity, specificity, and accuracy in the diagnosis of metamorphopsia were calculated against the Amsler grid. Results: Of 41 eyes, Amsler Grid detected metamorphopsia in 39.02%, and M-CHARTS detected metamorphopsia in 53.66%. The agreement rate of detection between the two tests was moderate (Kappa=0.52). M-CHARTS had a sensitivity of 87.50%, a specificity of 68.00%, a positive predictive value of 63.64%; and a negative predictive value of 89.47% for the diagnosis of metamorphopsia compared to the Amsler grid. The presence of PED in OCT was significantly associated with metamorphopsia. Conclusion: M-CHARTS can be a useful ancillary test to detect and quantify metamorphopsia even after fluid resolution in CSCR. Structural changes in macular morphology as observed with OCT can predict the likelihood of metamorphopsia.

2.
BMC Public Health ; 24(1): 930, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556871

RESUMO

BACKGROUND: Latin American countries are often limited in the availability of food outlet data. There is a need to use online search engines that allow the identification of food outlets and assess their agreement with field observations. We aimed to assess the agreement in the density of food outlets provided by a web collaborative data (Google) against the density obtained from an administrative registry. We also determined whether the agreement differed by type of food outlet and by area-level socioeconomic deprivation. METHODS: In this cross-sectional study, we analyzed 1,693 census tracts from the municipalities of Hermosillo, Leon, Oaxaca de Juarez, and Tlalpan. The Google service was used to develop a tool for the automatic acquisition of food outlet data. To assess agreement, we compared food outlet densities obtained with Google against those registered in the National Statistical Directory of Economic Units (DENUE). Continuous densities were assessed using Bland-Altman plots and concordance correlation coefficient (CCC), while agreement across tertiles of density was estimated using weighted kappa. RESULTS: The CCC indicated a strong correlation between Google and DENUE in the overall sample (0.75); by food outlet, most of the correlations were from negligible (0.08) to moderate (0.58). The CCC showed a weaker correlation as deprivation increased. Weighted kappa indicated substantial agreement between Google and DENUE across all census tracts (0.64). By type of food outlet, the weighted kappa showed substantial agreement for restaurants (0.69) and specialty food stores (0.68); the agreement was moderate for convenience stores/small food retail stores (0.49) and fair for candy/ice cream stores (0.30). Weighted kappa indicated substantial agreement in low-deprivation areas (0.63); in very high-deprivation areas, the agreement was moderate (0.42). CONCLUSIONS: Google could be useful in assessing fixed food outlet densities as a categorical indicator, especially for some establishments, like specialty food stores and restaurants. The data could also be informative of the availability of fixed food outlets, particularly in less deprived areas.


Assuntos
Abastecimento de Alimentos , Alimentos , Humanos , Estudos Transversais , México , Meio Ambiente , Restaurantes , Comércio , Características de Residência
3.
BMC Nurs ; 23(1): 228, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38566088

RESUMO

BACKGROUND: Japan has been accepting foreign nurse candidates since 2008 under Economic Partnership Agreements (EPAs). As globalisation progresses, nurses from diverse backgrounds are expected to play an active role in the medical field. Using an interview survey, this study examined the factors associated with EPA nurses' willingness to continue working in Japan. METHODS: We conducted semi-structured interviews from January 2022 to July 2023 with eight EPA nurses and one EPA nurse candidate working in Japan to investigate the factors associated with foreign-educated nurses' willingness to continue working in Japan. The interview guide included items on the status of the daily performance of their duties, what they found pleasurable in their nursing experience in Japan, difficulties they encountered in carrying out their nursing duties, and their expectations of the Japanese staff around them. Data were analysed using thematic analysis. RESULTS: From the interview data, seven themes were extracted. To continue working in Japan, it was important for EPA nurses to be able to communicate with patients and colleagues, maintain self-esteem and motivation, be resilient, have support from EPA peers and family members, be accepted by others such as patients and colleagues, and be satisfied with the support they received. CONCLUSION: The EPA nurses experienced many difficulties after becoming nurses and tended to be isolated because of their non-Japanese status. The results suggest that not only support from colleagues and supervisors but also a general understanding of EPA nurses from Japanese society is necessary. As globalisation accelerates, the Japanese nursing field needs to understand the diversity of the nursing profession and build a support system that will enable them to continue to take pride and feel motivated in their work.

4.
Vet J ; : 106109, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599544

RESUMO

Point-of-care (POC) glucometry is commonly used in horses; however, measurement error with this method when analysing hypoglycaemic samples (<4mmol/L) is unknown. The objective of this study was to determine the precision and accuracy of glucometry in hypoglycaemic horses in comparison to a laboratory method of glucose measurement (LAB). Repeatability coefficients were 0.47mmol/L for POC and 0.09mmol/L for LAB, and coefficients of variation were 10% and 2.11%, for the POC and LAB methods, respectively. Systemic bias with the POC method was present, with a mean bias of -0.26mmol/L (95% limits of agreement: -0.88 - 0.37) in comparison to LAB, and <70% of measurements were within 20% of paired LAB results. Prior to use of glucometers, assessment of the diagnostic performance of the equipment is necessary, including determination of acceptable criteria and reference ranges for hypoglycaemic samples.

5.
World J Urol ; 42(1): 217, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38581590

RESUMO

PURPOSE: Prostate cancer (PCa) histology, particularly the Gleason score, is an independent prognostic predictor in PCa. Little is known about the inter-reader variability in grading of targeted prostate biopsy based on magnetic resonance imaging (MRI). The aim of this study was to assess inter-reader variability in Gleason grading of MRI-targeted biopsy among uropathologists and its potential impact on a population-based randomized PCa screening trial (ProScreen). METHODS: From June 2014 to May 2018, 100 men with clinically suspected PCa were retrospectively selected. All men underwent prostate MRI and 86 underwent targeted prostate of the prostate. Six pathologists individually reviewed the pathology slides of the prostate biopsies. The five-tier ISUP (The International Society of Urological Pathology) grade grouping (GG) system was used. Fleiss' weighted kappa (κ) and Model-based kappa for associations were computed to estimate the combined agreement between individual pathologists. RESULTS: GG reporting of targeted prostate was highly consistent among the trial pathologists. Inter-reader agreement for cancer (GG1-5) vs. benign was excellent (Model-based kappa 0.90, Fleiss' kappa κ = 0.90) and for clinically significant prostate cancer (csPCa) (GG2-5 vs. GG0 vs. GG1), it was good (Model-based kappa 0.70, Fleiss' kappa κ 0.67). CONCLUSIONS: Inter-reader agreement in grading of MRI-targeted biopsy was good to excellent, while it was fair to moderate for MRI in the same cohort, as previously shown. Importantly, there was wide consensus by pathologists in assigning the contemporary GG on MRI-targeted biopsy suggesting high reproducibility of pathology reporting in the ProScreen trial.


Assuntos
Neoplasias da Próstata , Masculino , Humanos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Detecção Precoce de Câncer , Reprodutibilidade dos Testes , Estudos Retrospectivos , Antígeno Prostático Específico , Biópsia , Imageamento por Ressonância Magnética/métodos , Gradação de Tumores , Biópsia Guiada por Imagem
6.
Indian J Crit Care Med ; 28(4): 387-392, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38585311

RESUMO

Background: Presently, many laboratories are equipped with automated system for antimicrobial susceptibility testing (AST) for minimum inhibitory concentration-based reporting which enables the clinician to choose the right antimicrobial for timely treatment of sepsis. The study aimed to assess performance of direct AST from blood culture positive broth using automated AST system for accuracy and time taken to release the report. Materials and methods: The present study conducted in a 25-bedded ICU in North India for 12 months. Single morphotype of bacteria on gram stain from positively flagged blood culture bottles were included, which was directly identified (using an in-house protocol) with MALDI-TOF-MS from positive blood culture broths. DAST was carried out from 200 such blood culture broths and results were compared with reference AST (RAST) which was also done using VITEK-2 using overnight grown bacterial colonies as per standard protocol. Results: Among 60 isolates of Enterobacterales, 99% categorical agreement for both E. coli and K. pneumoniae observed by two methods were tested for AST. Among non-fermenters, Pseudomonas aeruginosa showed a categorical agreement of 99.6%, as compared with Acinetobacter spp. and exotic GNBs, which showed 95-96% agreement. A significant difference of 18-24 hours was noted in time to release the report between DAST and RAST, for GNB and GPC both. Conclusion: Direct AST from positive flagged blood culture bottles can significantly reduce the time to release the bacterial susceptibility report by up to 24 hours, at the same time maintaining the accuracy. How to cite this article: Singh V, Agarwal J, Nath SS, Sharma A. Evaluation of Direct Antimicrobial Susceptibility Testing from Positive Flagged Blood Cultures in Sepsis Patients. Indian J Crit Care Med 2024;28(4):387-392.

7.
Environ Sci Technol ; 58(14): 6077-6082, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38556743

RESUMO

The Paris Agreement and the Minamata Convention on Mercury are two of the most important environmental conventions being implemented concurrently, with a focus on reducing carbon and mercury emissions, respectively. The relation between mercury and carbon influences the interactions and outcomes of these two conventions. This perspective investigates the link between mercury and CO2, assessing the consequences and exploring the policy implications of this link. We present scientific evidence showing that mercury and CO2 levels are negatively correlated under natural conditions. As a result of this negative correlation, the CO2 level under the current mercury reduction scenario is predicted to be 2.4-10.1 ppm higher than the no action scenario by 2050, equivalent to 1.0-4.8 years of CO2 increase due to human activity. The underlying causations of this negative correlation are complex and need further research. Economic analysis indicates that there is a trade-off between the benefits and costs of mercury reduction actions. As reducing mercury emission may inadvertently undermine efforts to achieve climate goals, we advocate for devising a coordinated implementation strategy for carbon and mercury conventions to maximize synergies and reduce trade-offs.


Assuntos
Dióxido de Carbono , Mercúrio , Humanos , Mercúrio/análise , Políticas , Clima
8.
Am J Ophthalmol ; 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38643892

RESUMO

PURPOSE: To compare intraocular lens (IOL) power prediction accuracy of the Eyestar 900 (EyeS900) and the IOLMaster 700 (IOLM700) based on estimated and measured posterior corneal power DESIGN: Retrospective, inter-instrument reliability study METHODS: Setting: Institutional. PARTICIPANTS: 225 eyes of 225 cataract surgery patients. MEASUREMENTS: Patients underwent measurements by both devices preoperatively. MAIN OUTCOME MEASURES: Spherical Equivalent Prediction Error (SEQ-PE), spread of the SEQ-PE (Precision) and the absolute SEQ-PE (accuracy) of each device using Barrett Universal II (BUII) formula with either estimated posterior keratometry (E-PK) or measured posterior keratometry (M-PK). RESULTS: Trimmed mean SEQ-PEs of EyeS900 E-PK, EyeS900 M-PK, IOLM700 E-PK and IOLM700 M-PK were 0.03, 0.08, 0.02 and 0.08 D, respectively with no significant differences between EyeS900 E-PK and IOLM700 E-PK (p=0.31) as well as between EyeS900 M-PK and IOLM700 M-PK (p=0.31). Statistically significant SEQ-PE differences were found when E-PK and M-PK were compared, regardless of the device used, showing hyperopic SEQ-PE in M-PK calculations. Excellent correlation and agreement in SEQ-PE were found between the devices for both E-PK (p<0.001,r=0.848, mean bias:+0.01 D, 95% LOA of -0.32 to +0.34 D) and M-PK (p<0.001,r=0.776, mean bias:-0.01 D, 95% LOA of -0.42 to +0.39 D). No significant differences were found comparing absolute SEQ-PE and precision of the devices. CONCLUSION: The Eyestar 900 and the IOLMaster 700 show comparable IOL power prediction accuracy by the BUII formula using either estimated or measured posterior keratometry. An adjusted lens factor may be required for BUII when utilizing measured posterior keratometry in both devices.

9.
BMC Musculoskelet Disord ; 25(1): 281, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609938

RESUMO

BACKGROUND: The Swedish Fracture Register (SFR) is a national quality register for all types of fractures in Sweden. Spine fractures have been included since 2015 and are classified using a modified AOSpine classification. The aim of this study was to determine the accuracy of the classification of thoracolumbar burst fractures in the SFR. METHODS: Assessments of medical images were conducted in 277 consecutive patients with a thoracolumbar burst fracture (T10-L3) identified in the SFR. Two independent reviewers classified the fractures according to the AOSpine classification, with a third reviewer resolving disagreement. The combined results of the reviewers were considered the gold standard. The intra- and inter-rater reliability of the reviewers was determined with Cohen's kappa and percent agreement. The SFR classification was compared with the gold standard using positive predictive values (PPV), Cohen's kappa and percent agreement. RESULTS: The reliability between reviewers was  high (Cohen's kappa 0.70-0.97). The PPV for correctly classifying burst fractures in the SFR was high irrespective of physician experience (76-89%), treatment (82% non-operative, 95% operative) and hospital type (83% county, 95% university). The inter-rater reliability of B-type injuries and the overall SFR classification compared with the gold standard was low (Cohen's kappa 0.16 and 0.17 respectively). CONCLUSIONS: The SFR demonstrates a high PPV for accurately classifying burst fractures, regardless of physician experience, treatment and hospital type. However, the reliability of B-type injuries and overall classification in the SFR was found to be low. Future studies on burst fractures using SFR data where classification is important should include a review of medical images to verify the diagnosis.


Assuntos
Fraturas Ósseas , Fraturas Cominutivas , Fraturas da Coluna Vertebral , Humanos , Reprodutibilidade dos Testes , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/epidemiologia , Suécia/epidemiologia , Estudos Retrospectivos
10.
Sensors (Basel) ; 24(7)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38610432

RESUMO

Introduction: This study aimed to validate the ability of a prototype sport watch (Polar Electro Oy, FI) to recognize wake and sleep states in two trials with and without an interval training session (IT) 6 h prior to bedtime. Methods: Thirty-six participants completed this study. Participants performed a maximal aerobic test and three polysomnography (PSG) assessments. The first night served as a device familiarization night and to screen for sleep apnea. The second and third in-home PSG assessments were counterbalanced with/without IT. Accuracy and agreement in detecting sleep stages were calculated between PSG and the prototype. Results: Accuracy for the different sleep stages (REM, N1 and N2, N3, and awake) as a true positive for the nights without exercise was 84 ± 5%, 64 ± 6%, 81 ± 6%, and 91 ± 6%, respectively, and for the nights with exercise was 83 ± 7%, 63 ± 8%, 80 ± 7%, and 92 ± 6%, respectively. The agreement for the sleep night without exercise was 60.1 ± 8.1%, k = 0.39 ± 0.1, and with exercise was 59.2 ± 9.8%, k = 0.36 ± 0.1. No significant differences were observed between nights or between the sexes. Conclusion: The prototype showed better or similar accuracy and agreement to wrist-worn consumer products on the market for the detection of sleep stages with healthy adults. However, further investigations will need to be conducted with other populations.


Assuntos
Sono , Esportes , Adulto Jovem , Humanos , Polissonografia , Exercício Físico , Fases do Sono
11.
Artigo em Inglês | MEDLINE | ID: mdl-38638045

RESUMO

BACKGROUND: Sepsis is a major health problem worldwide and is associated with high morbidity and mortality with every hour delay in initiation of therapy. A conventional method of blood culture and Antimicrobial Susceptibility Testing (AST) takes around 48-72 hours. Empirical antibiotics need to be administered until the sensitivity report is made available. It has been estimated that 20-50% of the empirical antibiotics are inappropriate, resulting in prolonged hospital stays, adverse effects, and emergence of drug resistance. Additionally, this also puts an extra financial burden on both the patients and healthcare settings. Performing direct Antimicrobial Sensitivity Testing (dAST) is an important tool to reduce turn-around time (TAT) by at least 18-24 hours, thus reducing morbidity and mortality among critically ill patients. METHODS: Direct AST (dAST) was performed from the positively flagged blood culture bottles received between December, 2021 to May, 2022 from Intensive Care Units (ICUs) on MuellerHinton Agar (MHA) using four drops of withdrawn blood. dAST was performed for six drugs: Ceftriaxone-30 µg (CTR), Piperacillin/Tazobactam-100/10 µg (PIT), Meropenem-10 µg (MRP), Ciprofloxacin-5 µg (CIP), Aztreonam-30 µg (AT), and Colistin (CL). The zone of inhibition was interpreted as per CLSI M100 ed32, 2022 guidelines. A parallel conventional method was also performed to examine for categorical agreement and disagreement. Identification was carried out using MALDI-TOF MS from the colonies that appeared on the dAST plate on the subsequent day. RESULTS: A total of 162 positively flagged blood culture bottles were included in the study. The majority of the Gram-negative organisms were from Enterobacterales (n=109), followed by Acinetobacter spp. (n=28) and Pseudomonas aeruginosa (n=25). Out of the 972 isolate-antimicrobial combinations, overall Categorical Agreement (CA) was seen in 936 (96.3%), whereas disagreement was observed in 36 with minor error (mE) in 21 (2.2%), major error (ME) in 7 (0.7%), and very major error (VME) in 8 (0.8%) when compared to the routine method. Categorical agreement (CA) of > 99% was seen in ceftriaxone (CTR) and ciprofloxacin (CIP). In comparison, the lowest CA was observed with meropenem (MRP) at 92%. Colistin dAST was performed using the E-strip method, and the result obtained was highly convincing, with an overall disagreement of only 1.2%. CONCLUSION: Rapid dAST from positively flagged blood culture bottles proved to significantly reduce the TAT from the time of sample collection to the first availability of antimicrobial susceptibility report with excellent categorical agreement of > 95% using the conventional disc diffusion method. Results obtained were within the acceptance criteria set by U. S. Food and Drug Administration (FDA) guidelines of > 90% categorical agreement for a new method. We were able to obtain excellent concordance for colistin using the E-strip method. Performing dAST not only saves a "day", but its proper implementation would save a "life".

12.
J Stroke Cerebrovasc Dis ; 33(6): 107700, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38570060

RESUMO

OBJECTIVES: With the rising global burden of stroke-related morbidity, and increased focus on patient-centered healthcare, patient reported outcome measures (PROMs) are increasingly used to inform healthcare decision-making. Some stroke patients with cognitive or motor impairments are unable to respond to PROMs, so proxies may respond on their behalf; the reliability of which remains unclear. The aim of the study is to update a 2010 systematic review to investigate the inter-rater reliability of proxy respondents answering PROMs for stroke patients. MATERIALS AND METHODS: Studies on the reliability of proxy respondents in stroke were searched within CINAHL, Embase, PsycInfo, and WoS databases (01/07/22, 08/07/22). Fifteen studies were included for review. ICC and k-statistic were extracted for PROMs scales and categorized as poor (0.80). Bias was assessed using the CCAT. RESULTS: Five studies reported PROMs with inter-rater reliability scores ranging from 0.80. Two studies reported activities of daily living (ADLs) scores ranging from 0.41 to 0.80 and 8 studies reported quality of life (QoL) measures with scores ranging from 0.80. Subcategories of these scales included physical (ICC/k-statistic 0.41- >0.8), cognitive (ICC/k-statistic 0.40-0.80), communication (ICC/k-statistic <0.4-0.80,) and psychological (ICC/k-statistic <0.40-0.60) measures. CONCLUSIONS: Proxy respondents are reliable sources for PROM reports on physical domains in ADLs, PROMs and QoL scales. Proxy reports for measures of communication and psychological domains had greater variability in reliability scores, ranging from poor to substantial; hence, caution should be applied when interpreting proxy reports for these domains.

13.
J Am Pharm Assoc (2003) ; : 102092, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38608755

RESUMO

BACKGROUND: Pharmacists have some prescriptive authority in all fifty states through dependent and independent prescribing. Data describing the volume and characteristics of pharmacist prescribing are not widely available, and these insights are critical to gauge the impact of regulations supporting pharmacist prescriptive authority. OBJECTIVE: To identify trends in pharmacist prescribing and compare them to primary care provider (PCP) prescribing trends by analyzing e-prescriptions initiated from electronic health records systems (EHRs) from 2019 through 2022. METHODS: This cross-sectional study used e-prescriptions from a national health information network to identify e-prescriptions ordered by pharmacists and PCPs from January 7, 2019, to January 1, 2023. E-prescriptions ordered by pharmacists and PCPs were analyzed to identify annual volume by prescriber type and most prescribed therapeutic classes. States with the highest volume of e-prescriptions ordered by pharmacists were identified. RESULTS: The number of e-prescriptions prescribed by a pharmacist increased 47% from 2019 (n=814,726) to 2022 (n=1,199,601). The number of pharmacists prescribing in 2019 was 1650, and this increased by 122% to 3664 in 2022. The number of e-prescriptions prescribed by PCPs increased by 4% from 2019 (n=927,890,123) to 2022 (n=965,803,376) while the number of PCPs prescribing increased by 8% from 2019 (n=364,995) to 2022 (n=394,753). CONCLUSION: Pharmacist e-prescribing increased across the four years studied while PCP e-prescribing modestly increased. Factors like access to technology, such as electronic health records, state regulations, and reimbursement impact a pharmacist's ability to prescribe.

14.
Artigo em Inglês | MEDLINE | ID: mdl-38613676

RESUMO

This study aimed to investigate agreement and discrepancies between parent proxy- and adolescent self-reports on assessments of adolescents' health-related quality of life (HRQoL), and the role that individual factors may play in parent-adolescent agreement, in a sample of adolescents with Tourette syndrome (TS) compared to a control group of healthy adolescents. Adolescents aged 12-18 years diagnosed with TS were recruited with their parents from primary and secondary referral centres. Adolescent healthy controls were matched for gender and age. Adolescents and each of their parents completed a set of questionnaires including a HRQoL evaluation of adolescent, the 'Vécu et Santé Perçue de l'Adolescent'. Mother-adolescent, father-adolescent and mother-father agreements on adolescents' HRQoL scores were investigated at individual and group level, both in TS and control groups. Data were available for 75 adolescents, 75 mothers and 63 fathers, in the TS group. Agreement between mother, father proxy-reports and TS adolescents self-reports of HRQoL varied from poor to good, without significant difference with the control group. In TS group, mothers and fathers underestimated adolescents' HRQoL in 'Psychological well-being' subscale and mothers underestimated it in 'Physical 'well-being' subscale, while controls overestimated adolescents' HRQoL in these subscales. Larger mother-adolescent discrepancies for 'Psychological well-being' and 'Physical well-being' subscales were associated with internalizing symptoms. Regarding future studies, comprehensive evaluation of the various dimensions of adolescents' HRQoL with TS requires the integration of the perspectives of both adolescents, mothers and fathers. Clinicians should take into account this point to provide comprehensive care and services.

15.
Psychol Sci ; : 9567976241239935, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630602

RESUMO

It is important for people to feel listened to in professional and personal communications, and yet they can feel unheard even when others have listened well. We propose that this feeling may arise because speakers conflate agreement with listening quality. In 11 studies (N = 3,396 adults), we held constant or manipulated a listener's objective listening behaviors, manipulating only after the conversation whether the listener agreed with the speaker. Across various topics, mediums (e.g., video, chat), and cues of objective listening quality, speakers consistently perceived disagreeing listeners as worse listeners. This effect persisted after controlling for other positive impressions of the listener (e.g., likability). This effect seemed to emerge because speakers believe their views are correct, leading them to infer that a disagreeing listener must not have been listening very well. Indeed, it may be prohibitively difficult for someone to simultaneously convey that they disagree and that they were listening.

16.
CHEST Pulm ; 2(1)2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38645884

RESUMO

BACKGROUND: Provider adherence to clinical treatment guidelines in COPD is low. However, for patients to receive guideline-aligned care, providers not only must prescribe guideline-aligned care, but also must communicate that regimen successfully to patients to ensure medication concordance. The rate of medication concordance between patients and providers and its impact on clinical management is unknown in COPD. RESEARCH QUESTION: To examine rates of guideline alignment and medication concordance and to identify patient-level factors that place patients at risk for these types of poor disease management outcomes. STUDY DESIGN AND METHODS: This study was a secondary data analysis of the Medication Adherence Research in COPD study (2017-2023). Participants were categorized into 2017 Global Initiative for Chronic Obstructive Lung Disease (GOLD) stage. Medication regimens were classified as aligned or nonaligned with 2017 GOLD guidelines. Nonaligned regimens were stratified further into overuse and underuse categories. Medication concordance between provider-reported and participant-reported regimens was determined. Factors associated with guideline alignment and medication concordance were evaluated using logistic regression. RESULTS: Of 191 participants, 51% of provider-reported regimens were guideline aligned, with 86% of nonaligned regimens reflecting overuse with an inhaled corticosteroid (ICS). Thirty-eight percent of participants reported different regimens than their providers, of which > 80% reflected participants not reporting medications their providers reported prescribing. Participants did not report long-acting muscarinic antagonists and long-acting beta-agonists at similar rates as ICSs. Greater symptom burden and absence of a pulmonologist on the care team were associated with both guideline misalignment and medication discordance. Cognitive impairment and Black race additionally were associated with medication discordance. INTERPRETATION: Guideline misalignment and medication discordance were common and were driven by overuse of ICSs and unreported medications, respectively. The patient-level factors associated with medication discordance highlight the importance of improving patient-provider communication to improve clinical management in COPD.

17.
Digit Biomark ; 8(1): 75-82, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38655376

RESUMO

Introduction: Wearable technology offers a promising solution to advance current rehabilitation strategies for post-operative orthopedic care. The aim of this study was to determine the level of agreement and concurrent validity of a smart knee brace compared to the gold standard measurement system GAITRite® for assessing lower limb gait parameters. Methods: Thirty-four healthy participants were fitted with the smart knee brace (Digital Knee®) on their dominant limb. Gait parameters (stride length, stride time, and gait velocity) were measured simultaneously using the Digital Knee® and the GAITRite® electronic walkway. Two walks were performed at a comfortable speed and two at a fast-walking speed. Results: At a comfortable walking speed, stride time was moderately valid (ICC2,1 = 0.66 s), and stride length and gait velocity demonstrated poor validity (ICC2,1 = 0.29; ICC2,1 = 0.41). All gait parameters demonstrated poor validity at a fast-walking speed (ICC2,1 = -0.16 to -0.01). Bias ranged from -0.08 to 0.28, with more clinically acceptable percentage errors at a comfortable walking speed (14.1-30%) versus at a fast-walking speed (26.4-42.6%). Gait velocity and stride length had substantially higher biases in the fast-walking speed compared to the comfortable walking speed (0.28 ± 0.39 m s-1 vs. 0.02 ± 0.21 m s-1; 0.15 ± 0.23 m vs. -0.04 ± 0.17 m). Limits of agreement were considered narrower for stride time compared to stride length and gait velocity. Conclusion: The Digital Knee® is a promising approach to improving post-operative rehabilitation outcomes in patients with osteoarthritis. The Digital Knee® demonstrated good agreement and moderate concurrent validity for measuring gait metrics at a comfortable walking speed. These findings highlight the opportunity of the wearable sensor as an intervention for post-operative orthopedic care. This was a laboratory-based study; thus, further research is required to validate the wearable sensor in real-world contexts and in patients with knee pathologies. Further, refinement of the algorithm for measuring gait metrics at slow- and fast-walking speed with the Digital Knee® is warranted.

18.
Am J Clin Pathol ; 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656386

RESUMO

OBJECTIVES: Few cytologically indeterminate thyroid fine-needle aspirations (FNAs) harbor BRAF V600E. Here, we assess interobserver agreement for The Bethesda System for Reporting Thyroid Cytopathology (TBSRTC) category III (atypia of undetermined significance [AUS]) FNAs harboring BRAF V600E and contrast their features with those harboring non-BRAF V600E alterations, with attention to cytopathology experience. METHODS: Seven reviewers evaluated 5 AUS thyroid FNAs harboring BRAF V600E. To blind reviewers, cases were intermixed with 19 FNAs falling within other TBSRTC categories and in which genetic alterations other than BRAF V600E had been identified (24 FNAs total). Interobserver agreement against both "index" and most popular ("mode") diagnoses was calculated. Four additional BRAF V600E cases were independently reviewed. RESULTS: Reviewers included 3 trainees and 3 American Board of Pathology (board)-certified cytopathologists. Board-certified cytopathologists, whose experience ranged from 2 to more than 15 subspecialty practice years, had known AUS rates. BRAF V600E was identified in 5 of 260 (2%) AUS FNAs. Interobserver agreement was higher among cytopathologists with more experience. Mode diagnosis differed from index diagnosis in 6 of 11 cases harboring RAS-like alterations; mode diagnosis was AUS in 4 of 5 BRAF V600E FNAs. CONCLUSIONS: Atypia of undetermined significance of thyroid FNAs harboring BRAF V600E is uncommon yet relatively reproducible, particularly among pathologists with experience. It is advisable to sequence BRAF across V600 in such cases.

19.
Qual Life Res ; 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656407

RESUMO

PURPOSE: Proxy assessment can be elicited via the proxy-patient perspective (i.e., asking proxies to assess the patient's quality of life (QoL) as they think the patient would respond) or proxy-proxy perspective (i.e., asking proxies to provide their own perspective on the patient's QoL). This review aimed to identify the role of the proxy perspective in explaining the differences between self-rated and proxy-rated QoL in people living with dementia. METHODS: A systematic literate review was conducted by sourcing articles from a previously published review, supplemented by an update of the review in four bibliographic databases. Peer-reviewed studies that reported both self-reported and proxy-reported mean QoL estimates using the same standardized QoL instrument, published in English, and focused on the QoL of people with dementia were included. A meta-analysis was conducted to synthesize the mean differences between self- and proxy-report across different proxy perspectives. RESULTS: The review included 96 articles from which 635 observations were extracted. Most observations extracted used the proxy-proxy perspective (79%) compared with the proxy-patient perspective (10%); with 11% of the studies not stating the perspective. The QOL-AD was the most commonly used measure, followed by the EQ-5D and DEMQOL. The standardized mean difference (SMD) between the self- and proxy-report was lower for the proxy-patient perspective (SMD: 0.250; 95% CI 0.116; 0.384) compared to the proxy-proxy perspective (SMD: 0.532; 95% CI 0.456; 0.609). CONCLUSION: Different proxy perspectives affect the ratings of QoL, whereby adopting a proxy-proxy QoL perspective has a higher inter-rater gap in comparison with the proxy-patient perspective.

20.
BMC Ophthalmol ; 24(1): 182, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649848

RESUMO

BACKGROUND: The precision of anterior segment biometric measurements in eyes has become increasingly important in refractive surgery. The purpose of this study is to assess the repeatability of the automatic measurements provided by a new spectral-domain optical coherence tomograph (SD-OCT)/Placido topographer (MS-39, CSO) and its agreement with a swept-source OCT (SS-OCT) biometer (CASIA SS-1000, Tomey) in patients with myopia. METHODS: The right eye of 235 subjects was scanned 3 times with both devices. The evaluated parameters included central corneal radius of the steep meridian, central corneal radius of the flat meridian, mean central corneal radius, thinnest corneal thickness, central corneal thickness, anterior chamber depth, corneal volume and diameter. The intraobserver repeatability of the MS-39 measurements was calculated using intraclass correlation coefficient (ICC), within subject standard deviation, coefficient of repeatability, coefficient of variation and repeated-measures analysis of variance of the 3 repeated measurements. The agreement between the two devices was evaluated by 95% limits of agreement (LoA). RESULTS: The majority of the parameters acquired from MS-39 showed high repeatability. The repeatability of corneal diameter was slightly lower than the other measurements, although the ICC remained high. Agreement with the CASIA SS-1000 was good, indicated by the Bland-Altman plots with narrow 95% LoA values for all parameters assessed. CONCLUSIONS: The high repeatability of automatic measurements by the new device supports its clinical application in eyes with myopia, and the good agreement between the two devices indicates they could be used interchangeably for the parameters evaluated.


Assuntos
Segmento Anterior do Olho , Córnea , Topografia da Córnea , Miopia , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Masculino , Feminino , Adulto , Miopia/diagnóstico , Miopia/fisiopatologia , Topografia da Córnea/métodos , Topografia da Córnea/instrumentação , Reprodutibilidade dos Testes , Segmento Anterior do Olho/diagnóstico por imagem , Segmento Anterior do Olho/patologia , Adulto Jovem , Córnea/diagnóstico por imagem , Córnea/patologia , Pessoa de Meia-Idade , Biometria/métodos , Adolescente , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...